Sign In | Join Free | My chinacsw.com |
|
Brand Name : SKYLINE
Model Number : SL-PL06
Certification : CE ISO
Place of Origin : DONGGUAN CITY
MOQ : 1 SET
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 200Sets/Month
Delivery Time : 7 working days
Packaging Details : Export packaing
Flow control valve : ±0.1L/min
resolution : 0.001L/min
Flow meter : can measure air flow at 5L/min and 10L/min, at least accurate to ±0.2 L/min
Manometer : able to measure at least 4Kpa of pressure
Manometer accuracy : ±0.1kpa
Elastic tube : can be equipped with 7~14mm hose, can measure 6~16mm specification pen cap
Control mode : LCC touch screen control
Pen cap test components : self-locking quick interface, connect the pen cap convenient and fast
Gas source device requirements : in the pressure range of 4kPa ~ 50kPa, stable flow is at least 25L/min
This machine is based on the "GB21027-2020 General Requirements for the Safety of Student Products" standard (i.e., under the pressure of 1.33KPa, the air ventilation of the pen cap must reach 8L/min), which is a special testing instrument customised for pen cap air permeability testing.
(i.e. under 1.33KPa pressure, the air ventilation of the pen cap must reach 8L/min), and it is a special testing instrument customised for pen cap ventilation testing. It is a special testing instrument customised for pen cap aeration testing. It is mainly used to insert the pen cap completely into
The main purpose is to insert the pen cap completely into an elastic tube with a suitable diameter, air circulation and pressure difference at both ends, in order to measure the air flow of the pen cap.
① BS7272-1/-2: 2008 Safety standard for choking prevention of pen caps and pens plugs
② JTS S 6060:1996 Safety requirements for writing pens and marker pens caps for children up to and including 14 years of age
③ ISO 11540:1993 Safety requirements for writing pens and marker caps for children up to and including 14 years of age
④ GB 21027:2007 General requirements for the safety of student products
⑤ GB/T 24110-2009 Safety requirements and test methods for pen caps and end caps for import and export pen products
Flow control valve | ±0.1L/min/resolution 0.001L/min |
Flow meter | can measure air flow at 5L/min and 10L/min, at least accurate to ±0.2 L/min |
Manometer | able to measure at least 4Kpa of pressure. |
Manometer accuracy | ±0.1kpa |
Elastic tube | can be equipped with 7~14mm hose, can measure 6~16mm specification pen cap |
Control mode | LCC touch screen control |
Pen cap test components | self-locking quick interface, connect the pen cap convenient and fast. |
Gas source |
In the pressure range of 4kPa ~ 50kPa, stable flow is at least 25L/min |
![]() |
Air Flow Test For Writing Instruments ISO 11540 Pen-Cap Air Flow Tester Images |